Home Creators Posts Import Register Favorites Logout

Content

I’m going crazy trying to do this Cell Weight/Size table, spending wayyyyyyy too much time on it!

I need your feedback regarding adding gravimetric energy and power density numbers (Wh/kg and W/kg) along with the cell weight/size numbers.

Some questions…

  • Worth doing? Or is a simpler table okay, with just datasheet and actual weight/size numbers?

  • Both energy and power density numbers? Just one?

  • Use the volumetric numbers (Wh/L and W/L) instead? I’m not doing both gravimetric and volumetric. 🙂

  • At what current levels should the density numbers be calculated at? A very low current level, like 1A, so all cells can be directly compared? At the cell’s rating (which will be a bunch of different numbers)? I don’t want to do this for multiple current levels for each cell.

  • If power density is included, at what point in the discharge should it be calculated at? At what current level…1A so all cells can be directly compared?

You can see how something as simple as including cell density can quickly get pretty complicated!

What numbers (and how they’re determined) will be the most useful to you? Which would help you choose the best cell for your application?

Comments

Francisco Javier Durán

Probably the easiest would be putting everything I’d you have the data anyway 😆 Personally I’m not interested in 0,1mm size difference. Lately comparing my builds between JP30 and 30PL and 60W and other 21700 I had I would be interested more in weight. Not necessarily Wh/kg but of course I would enjoy to see that figure. I think calculated on the current used for checking the nominal capacity (?). For Power/kg and/or Vol 😆 I was thinking the same. Difficult to say. The easiest using an integral and making and average 😆 Maybe between 5-30 seconds (?) or 3sec to 1Min. But at 40A for power cells? Some cool ones could fall out. At least you are not bored 🤣 :))) Have a nice Friday!! Isn’t there middle in the night 😱 😴

EUCrusade

I think energy density and power density are such abstract measurements as they don't directly translate to much. Most use cases I (as a hobbyist) can think of you are going off of wanted energy and power"headroom". If the pack overall is 10mm longer or taller(~50-200 cells in a pack) doesn't amount to much in cell selection atleast personally. Weight is the same IMO, doesn't matter if the pack weighs 17.5kg or 17.6kg. 6.5Ah is 6.5Ah no matter weight or size, so I can draw 6.5A for 1h or 13A for 30min etc. Those numbers translate to something tanglible. Larger installations and scale is where I think these two values gain some ground. Or professional stuff. They are useful when comparing chemistry type advancements, new generations of cells or cell formats. But for hobbyists, I don't see many cases where these numbers actually make a difference. If you do decide to implement those though, I think the max continuous current is the point at which to measure. That creates caveats and makes the cell data not directly comparable, but captures the "performance profile" of the cell, as picking an arbitrary value every cell can reach handicaps power cells in a way that makes them look worse for capacity while only marginally differentiating them from each other, if at all. My 2 cents

Sco00

I like: - peak W / Wh to compare power per energy stored (Kind of C-rating) - peak W / kg to compare power per kilo - Avrage w / kg - Wh / kg to compare energy per kilo - Current typically is tested at 0.2C which i like because it is not easier for better cells. Comparing at same 0.2C would instead of simulating 1 cell vs another for a specific amount of cells compare if I have a specific Wh size of a pack and different amount of cells.

Frank

I think I would prefer gravimetric numbers instead of volumetric. Maybe use 50% of max recommended continuous current?

OverStack

-worth doing ? Yes ! Very much ! -Most relevant numbers ? Maybe power for power cell, energy for e cell, and both for hybrids ? I'd quote both in all cases -PLEASE quote gravimetric, as volumetric is 99% useless in round cells, only clearances can matter -Energy at 1C or 2C would be perfect -power density could be standardized at for example w/kg @50% SoC and max continuous rating without temp limit for a full discharge. I think this number alone account for the most variables If i had to pick 2 numbers: -wh/kg @1C to 2.8V -w/kg @50%soc as described Keep it up mooch your work is really worth it 💪

Battery Mooch

How would you define “peak W” for all the different cells? And “average W”?

Sco00

This is not easy and since there are so many load casese it is hard to define. But i do have my own way. 1. Peak W: This is hard because it is so dependent on time of the load, cooling, how hot the cell is and if it is really reasonable to load it at example 200A for 5 secounds. For my own comparison I compare cells at different loads and try to see what seems reasonable for a use case. To compare I ofthen look att how far they sag when drawn 10% of capacity at the highest ampere they can give without issue or going below like 3.2V (to have some margin using at lower than fully loaded. I like to use capacy instead of time just because it is att "full sag" and the time adapts with load. Your 100A tests is a good comparison between cells but does not show peak W. 2. Avrage w / kg. For my own comparison i check at what current untill the cell drops to 3.5V at 20% of capacity Ah is drawn. I like this due to it is possible to see at what Amp the cells has simlar "stress". I think cells usualy has done most saging at 20% and 3.5V seems to me kind of normal sag for continous draw for different cells compared to manufacturer recomendation. I also check if it can handle that load without over heating (Not super critical since cells can be watercooled).