Just some video of me updating my wiring I did for my heater to better meet code. I hope I didn't miss anything this time!

Have fun and happy new year!

Files

Previews only

30 Amp DIY Wiring Updates for 4000W Heater

Remember my video I installed a heater: https://youtu.be/yGAJDhl11ZE I went back and made some necessary changes thanks to your comments! Support ElectroBOOM: http://patreon.com/electroboom Checkout my merch: http://teespring.com/stores/electroboom Checkout my Amazon picks (my affiliate link): https://www.amazon.com/shop/Electroboom Post your submissions to: http://reddit.com/r/electroboom My Facebook: http://www.facebook.com/ElectroBOOM My Twitter: http://twitter.com/electroboomguy My other articles: https://www.electroboom.com/ Thanks to http://CircuitSpecialists.com and http://keysight.com for proving my essential lab tools and giveaways. Below are my Super Patrons with support to the extreme! Nicholas Moller at https://www.usbmemorydirect.com Sam Lutfi EIM Technology: https://www.eimtechnology.com/ Maestri Investment Group Ltd.: https://investmaestri.com/ Enter your school for tools: https://goo.gl/forms/VAgRre8rLVvA1cEi2 My sponsors and top patrons: http://www.electroboom.com/?page_id=727 By: Mehdi Sadaghdar --------------------------------------------------------------------------

Comments

Anonymous

Yup! This is why I always hire a licensed, bonded, and insured contractor for this sort of thing. BEZAN-LIKE-O!!

Peter Stevens

In Canada don't we have to get any new electrical wiring inspected? .. that or have an electrician do the job.

Anonymous

You shouldn't use the plastic connector inside the panel. The point of the metal connector is the bond the armour in case there is a break in the armour between each end. Then if there is a short to the armor and you touch it, you will experience yet another zap.

Anonymous

oh wow. don't know if my antishort red thingie comment was even worth saying! then, you did all this. for me? aw.

Thomas Eriksen

Your codes are weird, I'm used to the socket amp is a maximum rating, not a minimum… and if something is defined as fixed load I can reduce the wire size as long as a short on the end will trip the breaker immediately. I say I can because your codes are weird, if you follow our codes NEK 400 your get an shitty installation, but safe, it can always be done better than the codes

Cristian Klein

I love the brutal honesty around "sharing knowledge". 😁

Michael Mirsky

Yes, in Ontario I believe it really needs to be inspected but many people don't. But you run two risks. 1) a fire if you don't know what you are doing, and 2) if there is ever a fire due to wiring the home insurance might not cover it.

Anonymous

My house was built in 1936, we are renovating our kitchen right now. Finding all kinds of fun electrical errors.

Anonymous

happy new year Mehdi! Hope you had happy holidays with the family

Anonymous

After hiring a few licensed, bonded, and insured contractors, and then reading up and learning code and having to fix their work, I now don't hire them any more.

Anonymous

Oh god... I've bought two houses, and both were catastrophes in their own special ways. In one house the downstairs was wired correctly, but the upstairs was 50/50 reversed load & neutral - it also had 4 pairs of 3-way switches, and not one pair functioned correctly - and finally, indoor GFCI outlets were used in outdoor locations without any weatherproofing. All easy stuff to fix in the first couple days, but it was disconcerting. The other house had structural problems, so out of scope for ElectroBoom... and quite a bit more expensive to fix.

Anonymous

Did you forget the anti-short on the heater itself?

Wayne Parris

I have been wiring for a long time now. Never used "anti shorts" I just use flex fittings that does not require them. YMMV.