Home Creators Posts Import Register Favorites Logout

Downloads

Content

I won't keep you in suspense, so let's take a tour of what we can see in HYDRA 1.1F PRO :)______________________________________________________________________________1) New monitoring and the redesign of the HYBRID OC tab

*  The information about the switched off cores and CCDs has become more clear.* Color indication of cores that are active (orange) and those that are sleeping (green).* Added information about PBO2 limits (THM, TDC, EDC and PPT).* Added information about the memory controller (FCLK effective frequency , MEMCLK effective frequency and UCLK effective frequency).*  Added information about DRAM bandwidth (UMC RD and UMC WR).*  Added information about current AMD Curve Optimizer values.* EDC throttler - information about the current level of CPU load.* Added information about HOT SPOT and L3 CACHE temperatures.* The best cores (by CPPC) are marked with an asterisk.

* Added possibility to customize sensors (value processing and visibility). * Information from 23 sensors is available for each core.* Monitoring has been optimized, reducing the use of CPU time.* Reserved space for GPU monitoring.* The CO tables for HYBRID OC are now combined with the PROFILES tab for greater ease of use.* The color indication of voltages for the profiles will help you determine which voltage is energy efficient and which is not.* CO tables can be hidden for visual comfort.

* HYBRID OC got a frequency limiter for each of the cores. These values are filled in automatically during diagnostics, but can be changed by the user. Thanks to this innovation the stability of HYBRID OC has been improved.______________________________________________________________________________2) Redesigned AMD PBO2 tab and improved CO search

* Added ability to enable/disable AMD PBO2 (it was impossible to choose what to do in the previous version).* Added the ability to zero the CO values for each CCD individually.* AMD PBO2 now becomes part of the HYBRID OC profiles (I will talk about the future merge in May) therefore backup creation or download functions are now supported.* Dynamic PBO2 - this feature is in development.

* The search for CO values has been significantly refined with the new approach (pdf - guide is attached to the post). Of course, calibrations are planned.* Improved diagnostics customization: selection of voltages for testing as well as FFT MAX (previously FFT MAX = FFT MIN).* Added 3 presets with diagnostic settings (LIGHT, NORMAL and HEAVY) for users who want ease of use.* By default, the user gets the most optimal settings for testing. 1-click concept.______________________________________________________________________________3) Safety of the diagnostic process and other improvements

* If you were using AMD PBO2 but it crashed HYDRA ASSISTANT will help you to solve the problem the next time you start the application.* A new PHOENIX (restore the diagnostic process after a failure) was created to secure diagnostic data.  Only available for AMD PBO2 diagnostics. Temporarily.* For all types of diagnostics, the "stay awake" function is enabled by default to avoid the screen turning off or the system falling asleep.* Fixed and finalized PBO control for Cezanne processors.* The screen zoom factor is used to correctly load the location of the application.* Added a large number of tooltips. ______________________________________________________________________________

4) COMPARE  tab

* Now the user has the ability to compare not only the default system state with HYBRID OC, but also the default state with AMD PBO2.* For more information the graphs have a caption which comparison mode was used.* Also added is a graph with temperature comparison.

______________________________________________________________________________>> VIRUSTOTAL REPORT <<______________________________________________________________________________I am insanely grateful for everyone's support. These letters mean a lot to me. Now, with your permission, I want to spend a week resting so that I can start preparing the May update with renewed vigor. Believe me, I have something to surprise both you and AMD :)

Files

Comments

Doug Wilkinson

Thanks for the awesome update and hope you have a good week off 🙂

Joel Mahler

Can you confirm which version of Ryzen Master use are using? I tried Hydra 1.1E with Ryzen Master 2.9.0.2093 and got crashing due to a core not being able to clock stably at the tested speed. I had previously ran Hydra 1.0.0.7 with Ryzen Master 2.6.2.1818 and had no crashing issues. I'm just trying to get the stable tested & stable versions of each application. Thank you!

Jonathan H

Thanks for your work. Keep safe

Rory O'Donnell

Thank you yuri for this impressive update. Trying now!

Mikel Barrera

Thank you Yuri for everything. You're a great person. I hope soon that Ukraine rests in Peace and all the people who are with the shit of the War are punished before the Eyes of God by a thousand torments day after day for all their sins and genocides. It is admirable that with all the adverse circumstances you continue to do your job like this. You deserve all the best in life, you and all the people who know you and who you appreciate. Greetings Crack. Take care that you are worth a lot, and you know it. Just one question, Dram Calculator can be updated for Ryzen 3000 and 5000 series. It would be very useful.

ZeFluff

Much thanks for your hard work!

Timothy Yaeger

That's rest beyond well deserved. You're an inspiration, man!

Bill Bittel

Thanks Yuri. I hope that working on this can distract you, even if just a little, from what is happening in your country. I follow the war every day and feel so helpless. It looks like the US House finally came back from friggin vacation and got the Lend Lease bill passed. I hope that we can now get the weapons Ukraine needs into your hands a lot quicker than we have been doing. Please stay safe!

GM

1.1E crashed my system within a few minutes of finding CO even in safe mode with a brand new 5900X B2, this one seems to be rock solid! Thank you!

The_Lutzifer

There's no need to run Hydra with Ryzen Master. Uninstall Ryzen Master and try again.

GM

One question, how do you cap CPU VID in UEFI to 1.375V for PBO the way it is in HYDRA?

Martin Forst

Hello, I get following error message when pressing Activate HOC button: It is solved wit the redownload, Thank you very much.

Riano Andries

i keep getting EDC Limit reached error messages, and the diagnostic won't continue after a reboot

Yuri Bubliy

Ryzen Master is not required, the chipset driver or any other drivers are not required. Also, don't try to run HYDRA with a Ryzen Master, it will cause a big problem.

Yuri Bubliy

Thank you for those words! I think you will see the Calculator for DRAM in HYDRA as well as other important modules. Since the hydra is a mythical animal with several heads it fits the concept perfectly. Regarding Zen 3 support in the calculator - the presets have not changed, they are the same as Zen 2.

Yuri Bubliy

Yeah buddy, that's a really significant moment. Better late than never. Thanks for your support!

Yuri Bubliy

Unfortunately such a change is not provided by AMD that is why I create this project and in particular HYBRID OC, a place where you can configure everything.

Yuri Bubliy

Increase the limits for HOC max. EDC, TDC and PPT (SETTINGS tab).

Yuri Bubliy

I confirm this bug. I will release a fix, but you can also fix the problem by enabling "Using PBO2". I will update all the archives within half an hour.

Riano Andries

Thank you, and take care in this turmoil...stay safe

Mumpitz23

CCD1 is running in an endless loop while evalueating efficiency, crashing, reducing CO and Clock, crashing, reducing, crashing and so on. It wont reach creating profiles ever.

Kenjiin

had to revert back to 1.1E .. crashing every 15 minutes.. too sleepy to trace it..

Matteo Atzeni

Hi Yuri, how are you? I am a happy owner of a 5950X :) I wanted to report a possible bug: Once the diagnostics were done, I wanted to use the compare feature to visually compare the performance of the system. Unfortunately, however, I noticed that CCD 1 remains stuck at 546 MHz while CCD 2 arrives on all cores at 4.4 GHz. EDIT. I add that the problem also occurs when manually starting Cinebench.

Rory O'Donnell

Question for others since Yuri is on holidays. My Afterburner GPU usage is showing 65/70% playing doom eternal but my Task manager Performance tab says GPU 0 is only around 8%. Hydra seems to take the GPU 0 percentage when determining Game mode, is this an issue for anyone else?

Carl

I got a 5900x, and the same bug occurred. It also appears in CPUz stress test, my CCD1 is also stuck at 546 MHZ, and the benchmark result is very low.

Theo

Am i doing something wrong? HYBRID OC Tuned CCD#1 FREQ is only 546MHz while compare and BOOST TEST FREQ is low. ***HYDRA 1.1F PRO by 1usmus*** 05/03/2022 15:05:11 Microsoft Windows NT 6.2.9200.0 NVIDIA GeForce RTX 3080 Ti AMD64 Family 25 Model 33 Stepping 0, AuthenticAMD AMD Ryzen 9 5900X 12-Core Processor ASUS ROG CROSSHAIR VIII HERO BIOS ver. 3801 SMU ver. 56.53.00 TABLE ver. 3672069 Testing of the processor in the default state is now complete. Default score: 21469 Default VID: 1.18mV Default PPT: 142W Default TEMP: 56.8°C Default CCD#1 FREQ: 4247MHz Default CCD#2 FREQ: 4247MHz Testing of the processor in the tunned state is now complete. HYBRID OC mode Tuned score: 12940 Tuned VID: 1.25mV Tuned PPT: 113W Tuned TEMP: 60.9W Tuned CCD#1 FREQ: 546MHz Tuned CCD#2 FREQ: 4630MHz 15:38:27: Boost testing started! 15:38:54: Boost testing finished! HYDRA BOOST TESTER RESULTS CORE | AVG/MAX FREQ | POWER | TEMP | VID | C01 2720 / 2720 7.66 40.6 1.375 C02 2720 / 2720 7.8 42.2 1.375 C03 2886 / 4699 8.53 43.9 1.374 C04 2720 / 2720 7.87 42 1.375 C05 2720 / 2720 7.72 43 1.375 C06 2720 / 2720 7.65 42.9 1.375 C07 2720 / 2720 6.5 41.8 1.375 C08 2719 / 2720 6.53 40.3 1.374 C09 2720 / 2720 6.69 41.6 1.375 C10 2720 / 2720 6.55 40.2 1.375 C11 2652 / 2720 6.6 41.5 1.374 C12 2720 / 4700 6.65 40.8 1.374

mercyeyesd

Meeting the same bug. I somehow figure out why this happened and how to fix it. On the right end of profiles label there's a button shows HOC MAX FREQUENCY. Open it and you will find it only shows 7 Cores so you show scrool it to see all the cores. For some reason the max frequency will be filled by Hydra uncorrectly with only 50 MHZ. Once you enter every core with a right frequency such as 5000, the frequency bug will disappear. Remember to use your mouse to scrool to the bottom to make sure every core's freguency is correct. Even if there is only one core's max freguency is still 50mhz, all the cores' freguency will stay below 600mhz.

mercyeyesd

Meeting the same bug. I somehow figure out why this happened and how to fix it. On the right end of profiles label there's a button shows HOC MAX FREQUENCY. Open it and you will find it only shows 7 Cores so you show scrool it to see all the cores. For some reason the max frequency will be filled by Hydra uncorrectly with only 50 MHZ. Once you enter every core with a right frequency such as 5000, the frequency bug will disappear. Remember to use your mouse to scrool to the bottom to make sure every core's freguency is correct. Even if there is only one core's max freguency is still 50mhz, all the cores' freguency will stay below 600mhz.

André Calamari

Did someone manage to activate Hybrid Oc on this version? Mine gives an error with 5900x

Shawn Moss

Do I have to do both PBO2 tune and HOC tune?

Sakaana303

No as Yuri said on Discord. You should use PBO2 or HOC - not both togehter.

에르도

Do I have to do DIAGNOSTIC again every time a new update version comes out?

Kenjiin (edited)

Comment edits

2026-09-05 16:00 personally having A LOT of problems with 1.1F had to resort back to 1.1E.. everthing runs fine on 1.1F until the find voltages for AVX and FM3. thats when i get a repeating crash. my fat fingers cant click task maanager afast enough to cancel hydra from restarting.
2022-05-11 03:14

Yuri Bubliy

I advise not to use the best volt search function because this is analytical information that the enthusiast will use after his own evaluation. It is not necessary to include all functions that are available in the program. This feature will be eliminated in a future update.

Yuri Bubliy

There is indeed this problem with a number of processors that have an inflated base CO. They can go into an infinite loop. In a future update all functions of the CPU quality evaluation are removed as well as a new diagnostics is created from scratch.

Jamie Godwell

I've tested out 1.1F after running 1.0E happily for quite a while and I'm getting strange behaviour after the diag. I'm activating HOC & all frequencies are locking at 550mhz although the 'active profile' is swapping between the thread counts correctly - does anyone have some idea what could be causing this?

Jamie Godwell

Could this be a conflict with Process Lasso?

Dominic Maddox

I have the same issue, just finished running PBO2 Heavy for nearly a week!!! But now have problems where under any load CCD1 is locked at around 560MHz. Really sad as PBO2 seems to have done a decent job. Even disabling all Hydra functions I still have locked CCD1 low frequency. Only way to solve is close Hydra completely. Any assistance/suggestions would be great.

Arcao

I have problem with 1.1F version. After the diagnostic is finished, it shows me error: EXCEPTION IN MAIN TABLE, CCD1 FREQUENCY invalid value. Row 6! Any clue, what i am doing wrong? ***HYDRA 1.1F PRO by 1usmus*** 05/15/2022 07:55:11 Microsoft Windows NT 6.2.9200.0 NVIDIA GeForce RTX 3070 AMD64 Family 25 Model 33 Stepping 0, AuthenticAMD AMD Ryzen 9 5900X 12-Core Processor ASUS ROG STRIX B550-I GAMING BIOS ver. 2603 SMU ver. 56.69.00 TABLE ver. 3672069 DRAM speed 3600 MHz

Brian Horlor

Has anybody else had issues with instability after a diagnostic OC? I asked the software for a moderate OC of my 5950X since I want some extra speed but I also don't want instability). When I'm not using it for work, I have BOINC running on 2/3 of the cores. However, a couple times a day, I look at my computer and it's rebooted and is sitting at the login screen. Event viewer says that the previous shutdown was unexpected but offers no other info. Hydra, though it's running, doesn't seem to say anything since it's not doing a diagnostic. I tested the stability with 30 mins of CB23 and 1 hour of OCCT with no issues. Any ideas?

Kenjiin (edited)

Comment edits

2026-09-05 16:00 OK whoever responded to me i can't find my original post THANK YOU. i just ran the pbo2 find co and let it run. and 32k on r23 isnt bad what so ever. i did do a hardware mod with debauer and some other folks for pinouts but i managed to make the intel cryo cooler work properly with evc2 and the control module reflashed for amd and pbo2...i tested it with the 5800x because i was scared to get greedy and blow it up but managed to get the 5800x up to 5.8ghz and with the cryo on full send max temp at 1.475v was only 62degrees... now i just have to find a loophole so i can mass produce the module to fit and work with amd plug and play. i ll have a full write up and instruction guide (if you decide to attempt it) my only suggestion is make sure your b550 or x570 is a good overclocking board.. or your vrms will 100% fry lol. thanks to the guy that answered me tho i ll buy you a cookie if you pm lol
2022-05-15 22:54

Anonymous

oh PS. will be working on only the am4 because i have no plans on going to am5 platform unless am4 becomes that useless which in the way that yuri's progression of the program is going and the way that a lot more aftermarket parts will be much cheaper in the next months like 4000+mhz kits with cl14 under 200 bucks for a 32gb kit yeah ill stick to am4. that and from my understanding ddr5 is running into a shit load of problems with a lot of current rendering software .

Rory O'Donnell

it would be nice if we could configure a temperature value for a given profile, rather than a voltage

Jamie Godwell

@yuri any idea why CTR is triggering protection and my 5800x is dropping to 550mhz?

Jamie Godwell

***HYDRA 1.1F PRO by 1usmus*** 05/17/2022 10:15:06 Microsoft Windows NT 6.2.9200.0 NVIDIA GeForce RTX 3080 AMD64 Family 25 Model 33 Stepping 0, AuthenticAMD AMD Ryzen 7 5800X 8-Core Processor GIGABYTE B550 VISION D BIOS ver. F15a SMU ver. 56.69.00 TABLE ver. 3672325 DRAM speed 3800 MHz PCI-MUTEX holding time has expired! <<<< Retrying to send a command!

Anonymous

what i do is use argus monitor (premium) or fancontrol free github project. and create profiles specific to hydra profiles. if you have external pinouts on your mobo for temperature readouts that would actually be the best route because hydra would probably base a lot of its overclock or undervolt parameters on those numbers. i dont trust the onboard temps unless theyre actually pinouts. just from my experience from being a somewhat hardcore overclocker.

James Tiller

definitely something different with this build..... my 5950x is right at 23 hours of testing and showing no signs it is done. I am used to it taking half a day previously but this is a first.

Anonymous

dude it took me almost 36 hours but its stable as fuck lol. i suggest after its done go into your bios and check your ram.. cuz i was able to tighten and oc my ram a little more too.. went from 3866 16-20-19-19-38 to 3866 16-18-18-20-36 with 1.05 soc and 1.42 dram...i just stared at my new gpu for 36 hours and was waiting for it lol.

Mike Z

this sounds awesome, thanks

Arcao

Hi guys, I am trying to get AMD PBO CO2 values, but verification crashing on CORE 2 even with positive CO2 value 10. Is it normal? Or am I doing something wrong? ***HYDRA 1.1F PRO by 1usmus*** 05/19/2022 14:23:41 Microsoft Windows NT 6.2.9200.0 NVIDIA GeForce RTX 3070 AMD64 Family 25 Model 33 Stepping 0, AuthenticAMD AMD Ryzen 9 5900X 12-Core Processor ASUS ROG STRIX B550-I GAMING BIOS ver. 2603 SMU ver. 56.69.00 TABLE ver. 3672069 DRAM speed 3600 MHz Creating a basic configuration file for settings... Creating a basic configuration file for profiles... Phoenix ready! The search a CO for PBO2 has begun... Checking stability in a single-threaded load: STEP #1 CORE#1 CO: -10 14:25:42: BACKUP#1: saving intermediate values... 14:25:45: BACKUP#2: saving intermediate values... 14:25:45: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.351 TARGET DLDO VID: 1.297 FREQUENCY: 4674 TEMPERATURE: 73.9 14:26:54: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.351 TARGET DLDO VID: 1.327 FREQUENCY: 4700 TEMPERATURE: 74 14:28:03: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.324 FREQUENCY: 4700 TEMPERATURE: 73.4 14:29:13: Test #4 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.322 FREQUENCY: 4700 TEMPERATURE: 73.2 14:30:22: Test #5 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 At this CO CORE#1 is unstable, the CO is reduced. STEP #1 CORE#1 CO: -9 14:31:04: BACKUP#1: saving intermediate values... 14:31:07: BACKUP#2: saving intermediate values... 14:31:07: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.323 FREQUENCY: 4700 TEMPERATURE: 71.9 14:32:16: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#1 is unstable, the CO is reduced. STEP #1 CORE#1 CO: -8 14:33:22: BACKUP#1: saving intermediate values... 14:33:25: BACKUP#2: saving intermediate values... 14:33:25: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.33 FREQUENCY: 4700 TEMPERATURE: 72.1 14:34:34: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.348 TARGET DLDO VID: 1.308 FREQUENCY: 4674 TEMPERATURE: 73.4 14:35:43: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.307 FREQUENCY: 4674 TEMPERATURE: 73.2 14:36:52: Test #4 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.307 FREQUENCY: 4674 TEMPERATURE: 73.2 14:38:02: Test #5 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 At this CO CORE#1 is unstable, the CO is reduced. STEP #1 CORE#1 CO: -7 14:38:20: BACKUP#1: saving intermediate values... 14:38:23: BACKUP#2: saving intermediate values... 14:38:23: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.336 FREQUENCY: 4700 TEMPERATURE: 72 14:39:33: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.314 FREQUENCY: 4674 TEMPERATURE: 73.2 14:40:42: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.314 FREQUENCY: 4674 TEMPERATURE: 73.3 14:41:51: Test #4 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.314 FREQUENCY: 4674 TEMPERATURE: 73.3 14:43:00: Test #5 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.351 TARGET DLDO VID: 1.312 FREQUENCY: 4674 TEMPERATURE: 72.9 14:44:09: BACKUP#3: saving intermediate values... 14:44:09: BACKUP#4: saving intermediate values... Current CO values CORE | CO C01 -7 C02 -10 C03 -10 C04 -10 C05 -10 C06 -10 C07 -15 C08 -15 C09 -15 C10 -15 C11 -15 C12 -15 STEP #2 CORE#2 CO: -10 14:44:12: BACKUP#1: saving intermediate values... 14:44:15: BACKUP#2: saving intermediate values... 14:44:15: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -9 14:44:30: BACKUP#1: saving intermediate values... 14:44:33: BACKUP#2: saving intermediate values... 14:44:33: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -8 14:44:44: BACKUP#1: saving intermediate values... 14:44:47: BACKUP#2: saving intermediate values... 14:44:47: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -7 14:45:10: BACKUP#1: saving intermediate values... 14:45:13: BACKUP#2: saving intermediate values... 14:45:13: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.32 FREQUENCY: 4824 TEMPERATURE: 72.4 14:46:22: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -6 14:46:34: BACKUP#1: saving intermediate values... 14:46:37: BACKUP#2: saving intermediate values... 14:46:37: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.356 TARGET DLDO VID: 1.248 FREQUENCY: 4 TEMPERATURE: 51.9 14:54:29: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -5 14:54:40: BACKUP#1: saving intermediate values... 14:54:43: BACKUP#2: saving intermediate values... 14:54:43: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.298 FREQUENCY: 4774 TEMPERATURE: 74.4 14:55:52: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -4 14:56:04: BACKUP#1: saving intermediate values... 14:56:07: BACKUP#2: saving intermediate values... 14:56:07: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -3 14:57:14: BACKUP#1: saving intermediate values... 14:57:17: BACKUP#2: saving intermediate values... 14:57:17: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.326 FREQUENCY: 4800 TEMPERATURE: 72.8 14:58:26: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -2 14:58:39: BACKUP#1: saving intermediate values... 14:58:42: BACKUP#2: saving intermediate values... 14:58:42: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.34 TARGET DLDO VID: 1.314 FREQUENCY: 4774 TEMPERATURE: 73.2 14:59:52: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: -1 15:00:04: BACKUP#1: saving intermediate values... 15:00:07: BACKUP#2: saving intermediate values... 15:00:07: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.318 FREQUENCY: 4774 TEMPERATURE: 72.6 15:01:16: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 0 15:01:27: BACKUP#1: saving intermediate values... 15:01:30: BACKUP#2: saving intermediate values... 15:01:30: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.324 FREQUENCY: 4774 TEMPERATURE: 72.8 15:02:40: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 1 15:02:54: BACKUP#1: saving intermediate values... 15:02:57: BACKUP#2: saving intermediate values... 15:02:57: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 2 15:03:39: BACKUP#1: saving intermediate values... 15:03:42: BACKUP#2: saving intermediate values... 15:03:42: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.351 TARGET DLDO VID: 1.316 FREQUENCY: 4750 TEMPERATURE: 72.6 15:04:51: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 3 15:05:04: BACKUP#1: saving intermediate values... 15:05:07: BACKUP#2: saving intermediate values... 15:05:07: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.322 FREQUENCY: 4750 TEMPERATURE: 72.4 15:06:17: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.304 FREQUENCY: 4724 TEMPERATURE: 73.2 15:07:26: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 4 15:07:56: BACKUP#1: saving intermediate values... 15:07:59: BACKUP#2: saving intermediate values... 15:07:59: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.328 FREQUENCY: 4750 TEMPERATURE: 72.2 15:09:09: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.351 TARGET DLDO VID: 1.312 FREQUENCY: 4724 TEMPERATURE: 73.6 15:10:18: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.353 TARGET DLDO VID: 1.312 FREQUENCY: 4724 TEMPERATURE: 73.4 15:11:27: Test #4 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 5 15:12:04: BACKUP#1: saving intermediate values... 15:12:07: BACKUP#2: saving intermediate values... 15:12:07: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.314 FREQUENCY: 4724 TEMPERATURE: 72.3 15:13:17: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 6 15:14:05: BACKUP#1: saving intermediate values... 15:14:08: BACKUP#2: saving intermediate values... 15:14:08: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.348 TARGET DLDO VID: 1.32 FREQUENCY: 4724 TEMPERATURE: 72 15:15:17: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.326 FREQUENCY: 4724 TEMPERATURE: 73.5 15:16:27: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.326 FREQUENCY: 4724 TEMPERATURE: 73.5 15:17:36: Test #4 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 7 15:17:50: BACKUP#1: saving intermediate values... 15:17:53: BACKUP#2: saving intermediate values... 15:17:53: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.328 FREQUENCY: 4724 TEMPERATURE: 72.3 15:19:02: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 8 15:19:13: BACKUP#1: saving intermediate values... 15:19:16: BACKUP#2: saving intermediate values... 15:19:16: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.313 FREQUENCY: 4700 TEMPERATURE: 72.3 15:20:25: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.318 FREQUENCY: 4700 TEMPERATURE: 73.4 15:21:34: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.318 FREQUENCY: 4700 TEMPERATURE: 73.3 15:22:44: Test #4 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.318 FREQUENCY: 4700 TEMPERATURE: 73.6 15:23:53: Test #5 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 9 15:24:45: BACKUP#1: saving intermediate values... 15:24:48: BACKUP#2: saving intermediate values... 15:24:48: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.318 FREQUENCY: 4700 TEMPERATURE: 72 15:25:57: Test #2 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.354 TARGET DLDO VID: 1.324 FREQUENCY: 4700 TEMPERATURE: 73.2 15:27:06: Test #3 started! FFT MIN: 84 FFT MAX: 84 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.352 TARGET DLDO VID: 1.325 FREQUENCY: 4700 TEMPERATURE: 73.6 15:28:15: Test #4 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 TELEMETRY VOLTAGE: 1.35 TARGET DLDO VID: 1.302 FREQUENCY: 4674 TEMPERATURE: 73.4 15:29:25: Test #5 started! FFT MIN: 1344 FFT MAX: 1344 SMT: OFF DURATION: 60 At this CO CORE#2 is unstable, the CO is reduced. STEP #2 CORE#2 CO: 10 15:30:08: BACKUP#1: saving intermediate values... 15:30:11: BACKUP#2: saving intermediate values... 15:30:11: Test #1 started! FFT MIN: 4 FFT MAX: 4 SMT: OFF DURATION: 60 The "STOP" button is pressed. Stopping the process... TELEMETRY VOLTAGE: 0 TARGET DLDO VID: 0 FREQUENCY: 0 TEMPERATURE: 0 15:30:18: Stress test stopped. Phoenix deactivated!

Justin Montgomery

That’s good to know! I was about to comment and ask if anyone else had issues running the PBO CO test on heavy. I’m 3 days in and currently on step 43. 😅 Hoping for that same stability you’ve got!

Anonymous

holy jeebus i dont have that patience lol. i ll do the anti bad joojoo dance so it doesnt whea error you lol

André Calamari

I wonder if anyone tests this before going live, completely buggy. On Dynamic, CCD1 stays on 546mhz during AVX2 test, complete mess

Artem Batogovsky

Вітаю! Дякую за гарний інструмент. На віндовс 10 все було чудово, але потім оновився до віндовс 11 та отримав проблему - по перше в тих же тестах частота ядер та результати стали гіршими хоча налаштування наче не змінювались (в режимі PBO2). Крім того якщо гідра працює незалежно від режиме отримую постійні ривки в іграх, наприклад Witcher 3, раз на 30 секунд - 1 хвилину. Якщо гідру вимикаю - ніяких ривків нема. Я також використовую переназначення кращих ядер, бо мій процессор по замовчанню чомусь вважає що найгірше ядро то найкраще =) В чому може бути проблема, яке позбутись підвисань? І чи можна якось переназначити кращі-гірші ядра "назавжди" ? Чи в біос чи ще якось?

에르도

I wonder if I have to diagnose again whenever a new version comes out. Please reply.

F

Not every version i believe but for example the next version 1.1G has massive changes to the diagnosis process so it is of course recommended to do a new diagnosis.