Hi all! :)I was glad to see some serious feedback from you after launching the WISHLIST feature (links at the bottom of the page). This update is half of bug fixes, comfort improvements and new features such as: NVIDIA GPU management (RTX/GTX), a timing assistant(tips in log), improved CPU diagnostics (new tests(!)) + new comfort settings, support for RX-TUNER when iGPU enabled and an updated Overriding best cores (real-time SMT management)!Fortunately the situation in my city is calmer and I can devote extra time to the project. This means that the HYDRA project is getting bigger, and more interesting updates await you!  I want to thank each of you for your trust and support! -----------------------------------------------------------------TO USE THE AUTOMATIC UNDERVOLTING/OVERCLOCKING FUNCTIONS, INSTALL MSI KOMBUSTOR IN THE ROOT FOLDER OF THE APPLICATION!!!

CPU PROFILE COMPATIBILITY WITH THE PREVIOUS VERSION?

- YES.  ONLINE-GUIDE (1.3A) : LINK CHANGELOG:MISC* You choose where to minimize the application at OS startup: tray / taskbar / none (settings tab).* Overriding best cores - stability and performance update.

CPU DIAGNOSTIC* Additional security of diagnostics from third-party processes not controlled by the user.* It is possible to export (synchronize) AMD CO values from the AMD PBO2 tab to the dialog box with CPU diagnostics settings. The assistant asks.* The user will now have the ability to perform individual types of diagnostics so that time is not wasted on unnecessary diagnostic steps.* It is now possible to skip the raw AMD CO (or HOC CO) value search and go straight to the value verification. The assistant asks.* CPU diagnostics now checks for WHEA events.* Extra tests for CPU diagnosis have been added.* Increased speed and accuracy of CPU diagnostics. The first phase is a quick search for "raw" values, the second phase is a detailed verification.* Changed preset settings for CPU diagnostics. * Introduced a concept as Target VID - the maximum VID value that can be used by the diagnostician to search for HOC CO and create a 1T-4T profile. It affects the stability of HYBRID OC.* Fixed bug when system detecting wrong FFT value falsely stopped CPU diagnostics.* Alerts the user to background activity that negatively affects the accuracy of CPU diagnostics.* To avoid false detection of the error, the Prime95 log is deleted before each test run.

DCFR* New presets for DDR4 memory that is already in the app: 2*8 3866, 2*16 3866, 4*16 3600. * New presets for DDR5 memory that is already in the app: 2*16 6400. * Adjusting the rules for the CHECK TIMINGS function.* Fixed bug of incorrect RCDWR reading.* CHECK TIMINGS now logs the recommended values for the timings if the user wants to enter a completely unspecified timing value.* Unlocked management of some voltages for DDR5 memory.

GPU CONTROL* Enabled iGPU now does not block RX-TUNER operation.* Fixed a bug where adding or removing a new RX-TUNER profile did not deactivate the current profile switching process.* Added entry level monitoring for RTX and GTX graphics cards.* Added RTX/GTX-TUNER entry level. The user can manage CORE and VRAM offsets, temperature and power limits ,CORE voltage control.* Fixed bugs, which did not allow RX 7000 videocards to monitor and diagnose correctly.* Fixed a bug where RX-TUNER could not control multiple adapters at the same time. Note that the latest AMD drivers may block the use of multi-gpu.* Changed the default GPU diagnostic settings. In particular, it is recommended to use 4K resolution for reliable results.* GPU diagnostics now works better due to catching single artifacts. Accuracy has been improved.* Fixed a bug when it was impossible to adjust the curve of the fans.*  Fixed critical bug when HYDRA could not show any data after video driver crash, also HYDRA knows how to notify if video driver is damaged.* PHOENIX for GPU diagnostics now works properly (was previously disabled due to a change in diagnostic algorithms).* The PHOENIX WAKE UP! function also works to diagnose graphics cards.* Fixed bug when starting GPU diagnostics did not save disabled profiles state in RX-TUNER.* Added setting the duration of the VRAM test. 0 - do not test.WISHLIST:Would you like to write a wish? Do it in 2 clicks >> LINK Wish list report >> LINKVIRUSTOTAL:  LINK

Files

Comments

Shawn Schatzman

Why is the VRAM offset capped at +300? Using MSI Afterburner I can get a stable +800 VRAM. Heck I've seen some cards have a stable +1500 VRAM offset using MSI Afterburner...

Jan

I think GPU diagnostics runs in an infinite loop for some reason on my RX 6950 XT. My RX 6950 XT is apparently a bronze sample, especially when it comes to VRAM. VRAM cannot be overclocked at all. STEP #82 CORE VID: 1200mV POWER OFFSET: 0% CORE MAX FREQ: 2669MHz VRAM FREQ: 2248MHz 06:21:43: Saving intermediate values... VRAM AVG FREQ: 2225MHz CORE AVG TEMP: 66.7°C HOTSPOT AVG TEMP: 91.1°C ASIC AVG PPT: 285W Video card instability, artifacts found! The VRAM frequency has been reduced... STEP #83 CORE VID: 1200mV POWER OFFSET: 0% CORE MAX FREQ: 2669MHz VRAM FREQ: 2248MHz 06:25:22: Saving intermediate values... VRAM AVG FREQ: 2221MHz CORE AVG TEMP: 71.7°C HOTSPOT AVG TEMP: 96°C ASIC AVG PPT: 287W Video card instability, artifacts found! The VRAM frequency has been reduced... STEP #84 CORE VID: 1200mV POWER OFFSET: 0% CORE MAX FREQ: 2669MHz VRAM FREQ: 2248MHz

Tom Parkinson

To be fair to Yuri, it was listed above as "entry level support for GTX/RTX" - if there is currently no differentiation in software as to which card is installed other than it being an NVidia one, then 300 is a safe limit for all GTX/RTX cards, new and old. I am sure the maximum values will be increased in a coming update. :)

Yuri Bubliy

HYDRA works with real frequency (not effective). Just a conversion to a recognized standard. Monitoring and management. 100MHz HYDRA = 400MHz MSI AFTERBURNER, example.

Yuri Bubliy

2 sentences. 1) Do not reduce voltage for VRAM so that the graphics card can operate correctly at 2248MHz. 2) You can skip the VRAM test by setting the test duration to 0, but VRAM errors will be treated as CORE errors during the core test.

Shawn Schatzman

Thanks, I don't know why I didn't think to look for that.

Paolo Luppi

Hi i'm using Hydra 1.3G pro on Asus Prime B550 Plus & ryzen 7 5700x. Following the guide (is again for 1.3B pro rlease) when explain about "Recommended CPU LLC (Load Line Calibration)" for asus mobo don't consider other bios version (not all bios are created equal). On my bios don't have a setting step with number but with this option: auto, regular, medium, high & extreme. Yuri if i want to change from auto to other set what the set you suggest? Thank for any reply

Garey Smiley

With 1.4 (a & b) is anyone else getting a "Trojan:Win32/Wacatac.B!ml" virus warning? With 1.3 did not get any warnings.

Worm

i got 1.4b removed by bitdefender the instant i extracted the archive. 1.4a had no issues though. considering the track record of hydra i guess its a false positive but i'm not a security expert so take that with a grain of salt ...

Yuri Bubliy

False alarm. Why was there no false positive yesterday but there is one today? Any PCI bus or physical memory access driver has a 99% chance of being detected as malware. Obfuscation has a 99% chance of being detected as malware.

Yusuf Cem Kara

what is the meaning of "SMU unable to progress the command" ?

Rahid Ahmed

Please make "GPU FAN Temp/Speed Curve" make sense to me.

Rahid Ahmed

the only option that actually works on my end is "Zero Fan Mode" other than that no matter what parameters i change for fan-curve. Fan speed stays as default-AMD-STOCK fan curve. My-GPU: Gigabyte RX6800XT Gaming OC

Gijs007

Seems like Prime95 is not working correctly on my Zen4 build: According to the log It's constantly crashing and keeps increasing the AMD CO (I see a bunch of input similar to step 264, which I didn't include for the sake of irrelevant data.) STEP #264 Detailed analysis of the AMD CO value found... CORE#0 AMD CO: 40 06:28:34: Saving intermediate values... 06:28:35: Test #1 started! FFT MIN: 720 FFT MAX: 1344 DURATION: 200 MODE: AVX2 SMT: OFF Prime95 found instability! 06:28:39: CORE#0 AMD CO 40 unstable, AMD CO is reduced. STEP #265 Detailed analysis of the AMD CO value found... CORE#0 AMD CO: 42 06:28:40: Saving intermediate values... 06:28:41: Test #1 started! FFT MIN: 720 FFT MAX: 1344 DURATION: 200 MODE: AVX2 SMT: OFF An exception arose in phase 2! Phoenix disabled... This is the starting output: ***HYDRA 1.4B PRO by 1usmus*** 06/02/2023 06:17:02 Restoring the diagnostic process. Please do not take any actions. AMD Ryzen 7 7800X3D 8-Core Processor Stepping 2 GIGABYTE X670E AORUS XTREME BIOS F9a SMU 84.79.221 TABLE ver.5505284 DRAM speed 6000 MHz Non-standard configuration, 2 CCD's detected! Attempting to recover data from the general log... Phoenix enabled... The search a Curve Optimizer values has begun... Target PPT: 142 Target EDC: 0 Target TDC: 0 Target THM: 90 Target Fmax: 0 Update: Manually started Prime95. It doesn't like the large FFT's option (where it chooses the settings itself): I get the following error: No FFT lenghts available in the range specified Torture test settings that it came up with are: Min FFT size (in K) 15213 Max FFT size (in K) 15213 Memory to use (in MB) 28896 Time to run each FFT size (in minutes) 3 AVX 512 disabled When I run a custom one with min FFT set to 14335, and max to 15213. It works fine. Any higher minimum FFT will fail (with the same max).

Johnny Núñez

which is the hard test for zen4? detailed or by a3a3e11o? I'm using my pc for AI 7950x + RTX Ada a6000

Hyoo

Got the Same issue as GIJS007 Hydra keeps searching HOC CO raw values , while staying at a frequency of 3550. I had at one time 280#Steps for one core alone. At that point stoped the process ***HYDRA 1.4B PRO by 1usmus*** 06/04/2023 10:56:09 AMD Ryzen 5 5600X 6-Core Processor Stepping 0 ASUS TUF GAMING B550-PLUS BIOS 2806 SMU 56.70.00 TABLE ver.3672069 DRAM speed 3600 MHz Non-standard configuration, 2 CCD's detected! Active CCD: #2 Deleting obsolete diagnostic logs... Phoenix enabled... The search a Curve Optimizer values has begun... Target PPT: 88 Target EDC: 0 Target TDC: 0 Target THM: 90 Target Fmax: 0 STEP #0 Finding AMD CO raw values... CORE#0 AMD CO: -18 16:36:46: Saving intermediate values... 16:36:47: Test #0 started! 16:37:17: Saving intermediate values... 16:37:18: Test #1 started! 16:37:48: Saving intermediate values... 16:37:49: Test #2 started! Prime95 found instability! 16:38:05: CORE#0 AMD CO -18 unstable, AMD CO is reduced. STEP #1 Finding AMD CO raw values... CORE#0 AMD CO: -16 16:38:06: Saving intermediate values... 16:38:07: Test #0 started! 16:38:37: Saving intermediate values... 16:38:38: Test #1 started! 16:39:08: Saving intermediate values... 16:39:09: Test #2 started! STEP #2 Cinebench 1T test... CORE#0 AMD CO: -14 16:39:40: Saving intermediate values... 16:39:40: Test CB23 started! 16:39:59: CORE#0 AMD CO -14 unstable, AMD CO is reduced. STEP #3 Cinebench 1T test... CORE#0 AMD CO: -12 16:39:59: Saving intermediate values... 16:39:59: Test CB23 started! 16:40:19: CORE#0 AMD CO -12 unstable, AMD CO is reduced. STEP #4 Cinebench 1T test... CORE#0 AMD CO: -10 16:40:19: Saving intermediate values... 16:40:19: Test CB23 started! 16:40:39: CORE#0 AMD CO -10 unstable, AMD CO is reduced. ... STEP #245 Cinebench 1T test... CORE#0 AMD CO: 472 18:00:00: Saving intermediate values... 18:00:00: Test CB23 started! 18:00:19: CORE#0 AMD CO 472 unstable, AMD CO is reduced. STEP #246 Cinebench 1T test... CORE#0 AMD CO: 474 18:00:19: Saving intermediate values... 18:00:19: Test CB23 started! 18:00:39: CORE#0 AMD CO 474 unstable, AMD CO is reduced. STEP #247 Cinebench 1T test... CORE#0 AMD CO: 476 18:00:39: Saving intermediate values... 18:00:39: Test CB23 started!

blisscottii

i have a ryzen 7 3800x and a 6700xt oc and for some reason the app has never worked for my cpu and it just stopped working for my gpu im v confused on what i did wrong but ik it works

James Talley III

Since you have a Ryzen 3000 CPU, you should use Clock Tuner for Ryzen (CTR). HYDRA is for Ryzen 5000 and 7000 series CPUs.

Paolo Luppi

re checked my cpu/system with 1.4B now working fine after reset cmos :-)

未霜 阿菌

When using HYDRA 1.4B, if there is a single-threaded intensive load in the system, it is easy for HYDRA to encounter errors and eventually become unresponsive (manifested as HYDRA no longer automatically adjusting frequency and selecting the appropriate configuration file based on the current CPU load), and the following error will be seen in the log: PCI-MUTEX holding time has expired, retrying to send a command 92! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 92! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 92! 1: -1 2: -1 23:51:39: CMD_FAILED 92 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 23:51:39: CMD_FAILED 93 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 23:51:40: CMD_FAILED 93 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 23:51:40: CMD_FAILED 93 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 93! 1: -1 2: -1 23:51:40: CMD_FAILED 93 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 PCI-MUTEX holding time has expired, retrying to send a command 5! 1: -1 2: -1 23:51:41: CMD_FAILED 5 What could be causing this issue?

isolovyev

Yeah, I have the same issue...

Paolo Luppi

Before people run diagnostic is possible generate one automatic check for find if some program generate confllict with hydra? And i have another question after 5/6 hours hydra working normally the pc go in lock similar state. Luckily task manager working and is possible terminate the process and the pc starts working normally again. What can cause this problem? I'm using hydra 1.4B version.

Paolo Luppi

HI i think is a warnig about some coflict with other diagnostic program running simultaneously whit Hydra. In my case I have tested with aida64 extreme version. Not when Hydra is on diagnostic running, the manual show explicit raccomandation about this "It is not recommended to use third-party monitoring software during diagnostics, it may affect the accuracy of the data from the sensors", but in normal windows/personal computer running. I'm open hydra & instantly the warning is showed. I have the suspect for conflict with aida and i'm close aida with Hydra open. After i'm reopen aida and for trhee time the warning was showed. I hope Yuri solve this fastidous problem. But i hope PCI-MUTEX working fine even if SMU has this problem. If the user wants to use a permanent realtime diagnostic program with a window showing the various values of the system (cp/gpu frequencies, temperatures, voltages, fan speeds etc etc) Hydra can't prevent you from doing so. 06/15/2023 upgrade information If i'm using Autocad or adobe acrobat pro he warning about SMU is showed continously. Yuri please solve this fastidious issue because if the user working with normal sw like autocad or adobe acrobat pro is not a normal situation system warning the user about smu.

Mohammed Hussain

Hi, i'm unable to create profiles when i run any version of hydra newer than 1.2G. Is there something i need to clear or set up that will allow the newer versions of hydra to run through the diagnostics with profile creation? I'm on a 5800x3d with an Asus Hero(wifi) x570. Bios is set up and is on the latest version.

Christopher Lory

I am in the same boat - unable to create profiles or run the Find CCD CO values - it just says disabled. I am running a 7800x3D on a ASROCK x670e Steel Legend

Mohammed Hussain

I asked in the discord and it seems that options just doesnt work for x3d chips. HOC isnt suported for them :(

F A

Hi all.. is it possible to use the RTX Module without having an AMD CPU? Like to test the RTX management - have a 4070Ti (and a intel CPU)

Roney Cervinski

sorry im new here, why does it says CPU and GPU not Supported?

Jacob Lunde

So I cant seem to get the fan control to work at all, I have a 7900 XTX and no matter what it runs with Zero fan mode on, and doesnt care what my settings are. I am running in admin. Also (I am about to read the old ones in case its mentioned there) but no matter what I cant do the GPU additional power tune and tweaks test or the features (they are all greyed out so thats why I figured it was rolled back and isnt out for us currently) .

Night Owl

seems like diagnostic GPU using kombustor is not working, nothing appear after select menu (already install kombustor in root dir of hydra.)