Home Creators Posts Import Register Favorites Logout

Content

Taking a brief interruption from digital sound to bring you this.  From a Twitter poll, apparently more than half of "people" don't know what these do and why they're important.  I've always found them to be really neat, so I figured a video on them might be a good idea.

Pretty soon I'm gonna need a true outtro for all of the $10 patrons!  Wow!  I split you up into 2 columns today because my ending remarks were a little short.  It scrolled really really fast otherwise!

Files

The GFCI/RCD: A Simple but Life-Saving Protector

You can support this channel on Patreon! Link below These devices are a common sight in homes and businesses around the US and around the world. But what are they for? Why do we need them? This video explores the life-saving potential of the GFCI (known alias: RCD) and explains how they work. Do you like videos like this? Why not support the channel on Patreon! Funny, that last sentence was a question, but it’s said like an exclamatory statement. Odd, this English. Anyway, Patrons of the channel have enabled me to make this my job, and it’s really neat! I’d love to be able to make bigger and more elaborate videos, and with your help I can. If you’re interested in supporting the channel with a voluntary pledge, please check out my Patreon page. Thanks for your consideration! https://www.patreon.com/technologyconnections And thank you to the following Patrons! Charlie Quigley, Dakota Williams, Adam Erickson, Kevin Terrell, Tommi Hares, Trevor Smith, Thomas Fuchs, Callum Brieske, Tomas, Chuck Floyd, Eitan Tal, Emil Gilliam, Andy Copsey, Bitcore, Filip, Per 'Zapro' Jensen, Ward Sutherland, Örn Arnarson, Alberto Amatucci, etho624, Tomasz Kolinko, Carles Codony, Samuel Plainfield, Jason McMillon, TeaChest Media, Michael Pacheco, Jason Ganiatsas, Mike Gerow, Marc Schroth, Andrew J Thom, Samuel Blakey, Mrpirate707, Frank Harris, Joseph Spiros, Patrick Meister, Sergey Kiselev, Clara Latter, Ashley Grant, Scott Emmett O'Donnell, Tianyu Ge, jeekl, rozboris, Kelly Rose, Paul Fisher, Stephen Vrazel, Applied Science, Peter ford, Sophie Haskins, James Id, Brendan Sheehy, Jay Foreman, Rich Theobald, Kyle Olson, Bryan Reid, Quinton Wilson, Jeremy DeGuzman, Sean Spark, Lucas Hartbarger, Taylor Cuzela, David Lastres, Granger Meador, Jeremy Kitchen, Jason Wellband, Shane Belaire, Paul Emmerich, Matthew Rossi, Paul Craigie, Alex Smith, Nick, Tyler, Paul Williams, Steven Hidy, Fredrik Grufman, Kollin O'Dannel, RJ Kent, Yona, Kevin Strehl, Tony DeSimone, Mike Bailey, Maggie Brown, Howard Kraut, TM, Mark Nicholas Wales, T.J. Steckbeck, Pavlo Pravdiukov, Marco Anastasi, Peter Byrd, Trix Farrar, Matthew Razza, Mitchel J. Mullin II, Jakob Strande Langgaard, Jan Staval, Paul Walton, Matt Falcon, Steven First, Denver Alexander, Conor Hennessy Sykes, FinaleGrande, Christopher Dickey, OnlyOneSolutionTBHFam, Matt Sackett, Tim Juchcinski, Wayne Marsh, Ernie Smith, foophoof, Stein Strindhaug Don’t see your name? Don’t worry! To keep this little perk alive, the $5 patron shoutout is now on a rotating basis! If you’re not here, you should be here in one of the next two videos. If you’ve slipped through the cracks, don’t hesitate to send me a message via Patreon and I’ll fix it!

Comments

Rich Jeanes

I heard a contractor talking about having to install GFCI and Arc Fault. What is the difference?

Technology Connections

I had to look this up! Apparently they can detect when electrical arcing is occurring within a circuit, which is a leading cause of electrical fire. Actually pretty neat, since this is exactly the sort of fault a circuit breaker won't detect, yet sparks inside a wall or next to a stud could surely cause a fire.

Matt Whitlock

AFCI circuit breakers were already required by New Hampshire building code when my home was completed in 2010. So I have GFCI outlets on AFCI circuit breakers. Much protect, wow!

Michael Steeves

As an electrical engineer, I love your demo!

Peter Jerde

They're sensitive, too! I had an old fan whose on-off switch sparked a bit internally, especially if you turned the switch slowly. In my apartment, the bedroom outlets are on the one special arc-fault breaker in the panel. Sure enough, if the offending fan is plugged in to that circuit, it will trip when I get the switch to spark.

Staffan Ahlstrom

Thanks ! You certainly are an excellent taecher

Stephen Bell

"Will I ask a fourth question?" LOL, Alec. :-) We also call them ELCBs in the UK. Earth Leakage Circuit Breaker.

Robert

Interesting video, as always. So apparently the standard in Germany is a RCCB (Residual Current operated Circuit-Breaker, commonly referred to as a "FI-Switch") and they are located in the fuse box so every socket is protected by it. It's pretty surprising to me that not every socket in an US household is protected by this or something similar. Yes, if you have a faulty device you have to search for it but it isn't that hard because you still have the normal circuit breakers. Switch them all off and then on again one by one and when you get to the circuit with the faulty device the RCCB switches off again. So you can delimit the problem to a single room or area pretty fast. And I prefer to search for a faulty device for a few minutes to getting an electric shock because the socket wasn't protected.

Andy Aspaas

Prepare yourself for a YouTube comments section full of hate for US electrical codes. Has anybody actually studied this? I wonder how the US actually ranks in terms of electrical accidents worldwide.

Technology Connections

My gut feeling is that because we use 120V on general circuits, there a higher default safety level. And yes, I know that it's current that kills, not voltage, but a higher voltage penetrates farther into the body so in general lower voltage is safer. When around water, though, the insulating effects of your skin are greatly negated, hence the requirement of GFCI's. I have on a few occasions touched a live 120V wire with no ill effects--and I witnessed the same thing happen to my dad. With dry hands, it's dangerous alright, but usually not lethal. Just mildly painful and surprising.

Technology Connections

As I replied to Andy, I think some of the reason we don't think to put it in the breaker panel is that 120V electricity tends to be safer. With dry hands, getting a zap from 120 is rarely serious. So rather than protect every circuit, we just protect where the advent of wet skin increases the chances of a lethal shock. Not saying that's good, but it's probably the reason.

Kevin Kostka

I loved the main content, but also the little jokes here and there. [Will I ask a fourth question?" "In the shape of an L of her forehead."] Not only do we get a good technical overview, but it's extremely fun to watch!

peter ford

Here in Australia every circuit in the house has a "safety switch" installed as part of the main circuit board feeding power throughout the house. Every circuit is "safe" no matter where it's placed with the dwelling.

adcurtin

An electrician told me arc fault trips a lot, and they're not required anymore in Michigan. Ever flip a switch and hear a spark? plug something in and have it spark?

adcurtin

obvious protection isn't always the case. I've seen upstairs bathrooms with regular outlet protected by a GFCI in the downstairs bathroom. My house has an addition that had a hot tub in it, so everything needed to be GFCI. All the GFCIs are in the basement. There's even one for the lights and the fan, which are 10ft up.

nobody

My house's hot tub (located the US) has a 240V double breaker with an integrated GFI. Oddly, it only has a test button, and no reset button. Presumably it trips the whole breaker and you reset it by just turning the breaker back on. There is no "test monthly" wording anywhere on it, which I find a little disturbing.

Alberto Amatucci

If you might find interesting this anecdote: in Italy these devices are called, in colloquial/slang, "salvavita" - lifesaver. The install has been made compulsory in 1990