I'm not sure whether I should release the first video, this one with the flame test or both. Tricky.

And I still don't know the reason for the recall. Maybe a batch went out with the wrong plastic.

https://youtu.be/Bnbg6Jn1uNE

Files

Flame test on a recalled MK socket

After releasing the video of my first look at this recalled socket, my Patreon supporters suggested doing a flame test on it. So here it is.

Comments

Ex Cathedra

Both I'd say - it's not like you're saying anything critical to MK here and they were both interesting videos!

james knight

melty moments might upset the youtube monster😂 you and that lighter seem to make the monster tweak out.

devttyUSB0

add it on to the original, or release both. the fire test was interesting and i'm also curious to learn what is wrong with the thing that warants a recall!

Russell Couper

I've not taken many sockets apart but one thing could be the zinc coated steel earthing strap in addition to it only contacting with one side of the pin giving insufficiently low earthing resistance ?

Russell Couper

Maybe reach out and contact MK and ask them if they can give you the tech details for the recall??

Jon

What's the downside of releasing both?

Big Clive

In a way it feels like repetition.

Big Clive

It's odd because an arc flash usually needs phase and either neutral or earth in the immediate vicinity.

Big Clive

I'm definitely not going to do that.

Umbre

I'd recon it's the earth they recalled for.

Gadgetman

“The product presents a high risk of fire as it has been identified that when the switch on the socket is being switched on, or switched off, or whilst it is under load, there is a possibility for an arc flash to occur. This could cause the socket and surrounding materials to ignite, causing a fire. The affected sockets do not meet the requirements of the Electrical Equipment (Safety) Regulations 2016 or the Plugs and Sockets (Safety) Regulations 1994.”

tim1724

I'm not sure this one adds enough to risk possibly upsetting Youtube censors. I'd probably just put a note in the description of the original saying that the plastic wouldn't stay alight when you tried to burn it.

Macguru

it's been recalled, release it as a matter of public safety awareness ;-)

Namirred

The only thing I can think of is where the plugs plug in. I wonder if that causes movement of one of the parts going to the switch making enough of a gap for an arc.

jcx

My two cents say release it, but maybe you could combine the two, and have the flame test as a "Bonus Extra Footage" at the end (if you're worried about repetition?) :)

Jon Knight

If you're worried about YT punishing you for flamey fun, why not just put this video as unlisted (but public) on a second channel and then link to it from the description in the original less combustible first video?

Patrick Craenen

Sorry for the same YT URL I posted. I didn't see your comment.

Mike Page

Watching the eFIXX video I've just had a thought: it's Grenfell, isn't it? MK have reviewed all their stuff very conservatively and decided to pull some. That's just a guess.

Big Clive

There must be some reason for it. The plastic of this unit did seem to be self extinguishing, but with a carbon bridge the power could sustain arcing.

Yatuin

Flash to Internal Earth Bar - had "fun" of investigating identical situation while working for MK competitor. MK internal design is very similar to the one I've worked on. Main issue steams from BS standard requiring only 6mm distance between bars which in reality is not enough in specific conditions as we seen +12mm arcs initiated by switching operation. Unfortunately that fault can go unspotted during BS required tests due to some "vague" wording in test specifications and test setup