In hindsight I would have tested the capacitor differently. (Rectifier and a tungsten bulb in series to limit the current.)
But the fusible resistor did an admirable job of limiting the fault current and breaking the circuit.

https://youtu.be/HzteoG9gluU

Files

Exploring an LED bulb that went POP during a livestream

In hindsight, using an automated insulation tester to test for capacitor failure was not ideal. Aside from the fact that it was doing an automated test as opposed to just putting out the desired voltage, it probably also auto-discharged the capacitor after the test. It would have been much better if I'd tested the capacitor with a roughed up rectifier and powered it from the mains supply with a bulb in series to limit the fault current. The splattered rectifier could indicate that another component shorted out and damaged it, or it could have been the bit that failed. The fusible resistor did its job admirably, both limiting the fault current and then breaking the circuit decisively. Once again the current recording device decided that a high contrast black on white image was not something it could focus on. No wonder AvE gets mad at his camera. Quite miffed that the rubbery (polyurethane?) bumpers on my meters have started disintegrating. Maybe it's a sign that I should upgrade to new meters. Although I rarely do electrical testing these days. If you enjoy my videos, you can help support the channel with a dollar or two for coffee, cookies and gadgets, and keep it independent from the quirks of the YouTube algorithm by supporting me on Patreon. This also lets me link to my content on other platforms if YouTube uses the ban-hammer (again!) I release content for critique and feedback on Patreon as soon as it has been made. https://www.patreon.com/bigclive Alternatively, for a single contribution you can use PayPal:- https://www.paypal.com/paypalme/bigclive #ElectronicsCreators

Comments

Dave Frederick AKA @amorphuc

It was, as you probably realized, out of focus just for the schematic part. No big deal. You could still make it all out. Thanks Big Clive. Kind of an odd failure? I'd usually think the LEDs would fail mostly.

Gadgetman

I love the new multimeter - it’s the star of the show! Where did you buy it - AliExpress?

Mike Page

I wouldn't be happy with a fusible resistor that pinholed its surrounding heatshrink. If that was soldered down it could have caused other faults. They are supposed to fuse without any flame.

Mike Page

That DIT400 - yes, all the rubber overmould from that era is breaking down. I suppose they must be ~18 years old now. I don't know if newer products will have the same issues. As you say disappointing but it's not like you paid Fluke money for it ...

Mike Page

At 1.6mA, it only takes ~2s to charge 6.8uF to 500V. What you are seeing is the insulation algorithm trying to make sense of declining current as the dielectric absorption (soakage) settles. For reference, a Polarization Index test runs for 10 minutes. The important thing is you're getting a steadily moving reading rather than an unstable one. Also important for safety, the tester discharges the load at the end of test. If you want a pop you need to detach the leads with the test still running.

Big Clive

Yeah, I realized that the tester discharged the cap afterwards. Hindsight is a wonderful thing.

Big Clive

It was bought secondhand too. When someone upgraded to a combined tester.

Big Clive

I wonder if it was just a metal film resistor being used as a fusible one. Given the outer film construction I'd expect a bit of side action as it failed.