A test video in the new garage recording area, where I can accommodate bigger items.

It's a "classic" eBay under sink water heater, which I bought purely so we could take it to bits and see what the construction is like.

https://youtu.be/zI2ko2_6HZQ

Files

Inside an eBay "10L" 1.5kW under-sink water heater

The main advantage of undersink water heaters like this is that they store a preheated quantity of water for immediate delivery to the tap when it's used. They do different sized storage tanks and also vented and unvented versions. There's no waiting for the hot water to reach the tap. It's there almost instantly. They also just use enough energy to keep the well insulated tank at the preset temperature, so they are very efficient. The unvented version simply has a metal tank at full mains water pressure, and can feed standard taps/faucets. It does require understanding that while heating, the water will physically expand and it needs to be able to displace that expansion to a header tank or if fed directly from the incoming water main it needs an expansion tank and a safety pressure relief valve to prevent the tank from rupturing. If the tank did rupture, the unit is fed by full mains water pressure and would cause a flood. The vented version has a tank that is only at low pressure, as it relies on an open outlet at all times, and the tap simply supplies water to the tank on demand, displacing the preheated water out of the open port. That does rule out the use of standard taps though, and you have to use a specialist vented tap that has a single cold water feed that can either be diverted straight out of the tap for cold water, or diverted to the vented tank and then back up to the tap spout. The proper taps are expensive and you don't get much choice in style. One of the primary advantages of a vented system is that even if the tank fails it can only release the water that was in it at the time. So there's much less water damage. One quirk of the vented systems is that the taps drip while the water is heating and expanding. Once you get used to it you stop trying to turn the tap off harder! If you like the steampunk look you can make a very nice copper pipe vented system with a lever valve to send water to the heater and a big spout as the water outlet. Another major advantage of the under sink storage heaters is that they can be plugged into a standard socket or wired into a spur. Their power requirement is similar to a small kettle, and only while they top up the heat. These systems are not suitable for filling a sink or bucket with hot water. They only store a small quantity which is best suited to casual dish and hand washing. But for many applications they are perfect. I think the silicone smeared around the heating element is to seal it against accidental water ingress between the metal sleeve and ceramic, as that can cause earth leakage tripping issues. As usual the sellers have misdeclared the tank capacity. No great surprise for something from eBay. If you enjoyed this video, please consider subscribing for similar content. You can help support the channel with a dollar or two for coffee, cookies and gadgets, and keep it independent from the quirks of the YouTube algorithm by supporting me on Patreon. This also lets me link to my content on other platforms if YouTube uses the ban-hammer (again!) I release content for critique and feedback on Patreon as soon as it has been made. https://www.patreon.com/bigclive Alternatively, for a single contribution you can use PayPal:- https://www.paypal.com/paypalme/bigclive #ElectronicsCreators

Comments

Big Clive

It's well ventilated so it will be cold, but then I keep my whole house cold.

Charles

Very interesting. I'm in Canada; having a single central water heater for the whole home, with hot water distributed to every tap, tub, and shower is normal. Storage water heaters are the most common, though the instant-on-demand types show up here and there. I've never seen anything like your vented taps; water heaters are always pressurized. The safety pressure relief valve isn't connected to the water inlet or outlet, it's a separate pipe connection to the tank, at the top, with a plastic pipe directing the venting water down to the floor. The tanks do eventually fail. Depending on what the local water is like, it may be sooner or later. Without annual flushing of the tank, water heaters in my city tend to max out at 5-6 years. With flushing and changing the sacrificial anode regularly they can go much longer - my current tank is 13 or 14 years at this point. If you're lucky, they fail slowly, just dripping a bit and giving you lots of warning. But they can fail more dramatically, and flood the floor. Since they're normally installed in an unfinished room in the basement that has a floor drain, it's not a complete disaster. It's inconvenient and you do some mopping. It's mostly not an issue in apartments / flats because those generally don't have individual water heaters. They usually have a central boiler that supplies hot water for all the units. Differences between countries in this sort of stuff is fascinating to me.

NN Thomas

Thanks for the information, Clive. What would be the effect of having the cold water supplied from a cistern?

evilution

Nothing a couple of wall sound deadening panels won't fix.

adrian

That used to be the system in the UK and is still very common but for the last 10-20 years there has been a shift to 'combi' boilers which heat water on demand and divert to either radiators or hot water (via a heat exchanger - not the same water!). These don't have a storage tank but it's still centralised.

adrian

I think you need a dimmer, preferably not PWM (or use a high frequency). And I miss the little squiggle from the plastic welding tool. Glad to see that bench is still featured.

Martin Sowle

I like it. A little echo,ey but not distractingly so. Is that on the floor? It looks like a painted floor.

richard ockman

Video ok sound has a little echo. May need a dimer for the lights. The tank looks well made.For dielectric fittings a brass coupling or brass valve between the tanks fittings and copper lines would stop the galvanic effect, or the proper dielectric unions,which also make the tank easier to install or remove for service. The red RTV around the heating elements is to stop moist air being absorbed in to the insulation around the Nichrome element wire.

Dennis

Slight echo, the room needs more clutter 😂

Big Clive

It's disturbingly uncluttered at the moment.

Big Clive

It's an OSB benchtop with grey resin paint on it.

Big Clive

The slight issue being the probability of that area being used for welding.

Big Clive

From a water tank it could negate the need for the pressure release device by allowing slight expansion back up to the tank.

Mike Page

Sound is intelligible but there's a little slap and boom. Hang a rug or blanket on one or two walls you'll be amazed how much that tames the slap. The boom may be harder to treat because of wavelength.

Mike Page

Rockwool is good. And as others have commented - some clutter to diffuse the reflections.

Seán Byrne

I wonder if something like a PIR sensor wired to a solenoid valve on the inlet flow (before the pressure relief valve) could prevent the flood risk. This would also avoid someone accidentally running up a bill with the hot tap left running.

Dave Frederick AKA @amorphuc

Interesting. Thanks Big Clive. I was wondering off the top if you would have been able to zoom out just a little more to see the whole water heater? Not sure. I watch all your content on a 55" computer screen but I know you try to optimize for phone screens. I think the sound is fine with only the slightest amount of reverb perhaps. Then again, these 64 year old ears aren't what they used to be. The heater looks pretty much like this one sold here in the States for $63. Another listing of the same thing/different seller for $73 with nine mostly positive ratings. https://www.amazon.com/Electric-Mini-Tank-Portable-Bathroom-Cupboard/dp/B0D5LTPQ72?crid=1TMUBSJKPJ4X0&dib=eyJ2IjoiMSJ9.c8qvh1ccyhkMwkKt3_AyFqXHihP4tDgHVS3m2n6DO9s6gsJziYprAoCPa6s4vX1jIJ5_KATRHdEQK9m70eheA_7lY55cWldtcZMwXkqbk5pyVwGQ8qC_NH49xFSQA3a0V_0APa4CWJ4LwgsLa3gOmo96_yal76t7cRmz8NysXLtnHk4GuoV3IYrfXpKyFHRf7sQVnbB4y5rn4mz-WW-w2gNxhuZghsb6yRtth42GgSJnYnEmGNbk4IHeJLhTf8_HaMpzIzZ_4Bwk75Vlw_a16ATn8aoK2ko3y6-bQ2U3NMY.5TSpEzizAAIGWuo-516xSahkzCOc_-yYV_sF8-yHiuU&dib_tag=se&keywords=Electric+Mini+Tank+Water+Heater&qid=1750035332&sprefix=electric+mini+tank+water+heater%2Caps%2C186&sr=8-82&xpid=XVIoLJT8wegvM The average water pressure in Boise is 60 psi. I thought about getting one of these (preferably one with numerous high ratings?) for under the sink in my bathroom. Would there be a problem with connecting the hot water line to the cold inlet of the heater. I'd consider doing that for more instant warm water to wash hands rather than waiting 30 seconds for the hot water to get there?

Big Clive

I can move the camera a bit further up to get a wider view, but if it's too high it causes issues with seeing and using its touch screen. I installed a similar, but UK sourced and approved heater (Ariston) for my brother and did install it on the lower pressure tank-fed hot water line for exactly the reasons you describe, as it always took ages for the hot water from the main tank to reach the kitchen. In that instance, any expansion should be accommodated by the tank in the attic.

Big Clive

There are automatic valves that can shut off if water flows for longer than a preset time.

Big Clive

This area is intended for testing things like welders, so flammability of sound proofing is an issue.

Big Clive

It's an experimental large area flat panel lighting system, so shiny things like this case can still be an issue, but less so than with point sources of light.

Big Clive

It's only for specific videos of huge things that don't fit in the usual space and also pose a risk of sparks and flames.

Dave Frederick AKA @amorphuc

Cool. Thanks for the reply. I guess that makes that installation method a better route - good to know.