A look at a very standard snubber module from AliExpress that is used to help suppress arcing across switch/relay contacts and to protect triacs and prevent false triggering by snubbing fast transients.

Usually these use a 100 ohm resistor in series with a 100nF capacitor. This one is using a higher value resistor, which is fine. The addition of the MOV is interesting.

https://youtu.be/yb_Mi6W1cl0

Files

Snubber network module for protecting contacts

A classic snubber network is a 100nF capacitor and 100 ohm resistor in series. They are often used across switching contacts like relays or contactors to quench the slight arc when breaking high or inductive loads. They work by providing an alternative easier path for the arc "noise" than the air gap of the opening contact, shunting it and allowing the arc across the contacts to break. The resistor is used to limit the current through the capacitor, and also the current that could flow when the contacts close while the capacitor has a charge on it. With triac circuits the snubber can shunt voltage transients and also reduce the risk of the triac being falsely triggered by electrical noise or spikes across it, especially when switching inductive loads. The MOV (metal Oxide Varistor) on this module is an unusual addition that will provide extra protection against voltage spikes. If you enjoy my videos you can help support the channel with a dollar or two for coffee, cookies and gadgets, and keep it independent from the quirks of the YouTube algorithm by supporting me on Patreon. I release content without adverts for critique and feedback on Patreon as soon as it has been made. https://www.patreon.com/bigclive Alternatively, for a single contribution you can use PayPal:- https://www.paypal.com/paypalme/bigclive #ElectronicsCreators

Comments

Dave Frederick AKA @amorphuc

Very interesting. Thanks Big Clive. You always mention snubber networks and I've never really understood them.

Mike Hughes

Earlier this year, you did an autopsy on the switch from my Ferrex sander (https://youtu.be/uy2lrpDDNGI) So having watched this video, it got me wondering if these modules would protect these type of switches from failing prematurely?

Zeedijk Mike

Would love to see the waveform on a scope, with and without the snubber network. Just to see how effective it is.

Big Clive

It could definitely reduce pitting of the contacts on a regularly used switch.

Ymir the Frost Giant

a series of 'building block' vids like this would be very welcome.

Circuitmike

Same here! I've even watched YouTube videos the purport to explain snubber networks but I could never quite get my head around them. Like, why, in DC circuits, would you not just use a diode across relay contacts? Or why is there a resistor when I would think a capacitor would do the job alone? I think this video answered most of the questions I had about snubber networks.

John Huntington

Back in the 80s, I did a lot of relay logic and PLC-based control systems, and we used to use snubbers routinely. 20 or so years later, I went back and built some PLC-based stuff controlling some pneumatic valves for a haunted house, and I forgot the snubbers. My little PLC (which is usually bomb-proof) would actually reset and restart itself from the back voltage each time the pneumatic valve was fired. This caused a bizarre (and hilarious) loop where it would execute a head chop effect, crash from the back EMF, reset, execute a head chop, crash and reset, over and over, etc. I got out the laptop looking for an error in my code, and then finally recalled my electrical basics from two decades earlier. I installed a snubber, and after that the thing ran perfectly for years.

Mike Hughes

Thanks I am going to get some of those then as I have a drill press with the same problem now. Seems like it could save a bit of hassle in the future.