Home Creators Posts Import Register Favorites Logout

Content

I just bought this vintage electric shower from an eBay seller as being sold for spares.

It is one of the older units where the live 240V heating elements are literally in the water path, hence the long thin blue and red hoses looped inside to create a longer resistance path in the water, and the outlet is also earthed/grounded to shunt any residual current to ground.

The spares available for these include the entire heater block and just the bare coiled elements.

Can you tell which neon was the main power indicator?

Files

Comments

Ralph Shoop

Was it overdriven in addition to having a lot of hours on it perhaps?

Jeff Larson

Well this is really intriguing. I like that you can see through the chamber of the heater core. The triangular graduated chamber reminds me of a flow meter but I don't see a float and there seems to be a electrode at the top rather than a tube. Hmm...

Big Clive

100K resistor on 240V, so the neon probably had a short but glorious life.

Simon Arnold

The neon on the left/bottom?

Echo The Husky

I love the design of those dolphin showers! Still see them in service now and again.

Big Clive

I was hoping to find one of the type with the big flat panel with the heating element snaking through it. After buying this eBay suggested a NOS heater block (which I bought too.)

Echo The Husky

The coolest version has a Crabtree VOELCB in the top, the switch dolly operated by a string poking out either side of the casing IIRC.

Big Clive

I think I've seen that one with the weird pull-cord system. While hunting around for Dolphin stuff I found NOS bare coiled elements for repairing the heater block to element level.

Chris Hartley

I would say the one that was on all the time, and is now black (the leftmost one).

Moz in Oz

Power indication is the glowing eyes of the user who is also in the main current path?

Big Clive

If installed correctly with the earth in place and all metalwork in the bathroom bonded to create an equipotential zone, then it should actually be quite safe.

Big Clive

I think it might be some sort of flow indicator. That electrode seems to be associated with an over temperature device too.

Paul Reid

>10KV radio/TV transmitter tubes were often water-cooled, using ten-foot glass tubes for isolation with fairly ordinary water; and of course only trained attendants in the room.

Mat Fordon

Hahaha it got totally roached! Would that 100k resistor be sufficient to prevent this from cooking off on 120v?

Big Clive

It would be fine on 120. For 240V they normally use a value closer to 220K.

Chipmunk

I am guessing the black one... :) and thanks to dennis for this patreon membership, life's been hard :) .... never seen one of these beasts before, very nice, looking forward to the video sir

Chipmunk

I prefer 270k, just to give the thing a chance :)

Chipmunk

John Ward's video on how conductive normal (fairly hard where he is) tap water ISN'T was quite instructive

Chipmunk

mmm crabtree VOELCBs, lovely bits of kit, shame they're lethal now (mostly failed due to never being tested)

Mike Hughes

The one that is now posing as an infra red detector? :) I note that they are still using red and black for live and neutral, so this MUST be old.

Cookie

Just like the previous owner. "I need a hot shower to wake me up"

Robert

We have an electric shower, unsure how old, maybe over 10 years and the power light stays lit constantly. Unless I stop the power supply to the shower itself. Only then does the bulb extinguish

Ymir the Frost Giant

A shower? Could've fooled me, though that isn't difficult. Once you've reverse engineered it (in BC reverso-vision), you could get ElectroBoom to test it! If he ate some cornflakes at the same time they might do a bit more than snap crackle and pop before going soggy.

Nigel Walker

This reminds me of the sausage cookers where you basically plugged them into the mains. Totally safe, no really! Just swap people for sausages.

RonNona

Electricity and water still scares the crap out of me. (I live in the US)

richard ockman

Clive had videos of hot dog cookers and cooking different food items with AC line current but i think he took them down so Youtube would not give him grief.

IamFubar

This is something that I would love to own but would never EVER use in my shower!

Big Clive

Hi Chipmunk, I was wondering how you were.

Chipmunk

Thanks clive, and i am fine, financially not so much (hence dennis and others working to get me this back, thank you guys)... been a bit mentally under the weather due to stress from the above, but at least not under a live shower! ... i can see an end now though :)

Chipmunk

it's just a 'tankless water heater' but.... being in the area OF the shower itself is what freaks out non brits, it relies on the clever design of the enclosure typically to keep the water OFF the spicy bits. These days they could design it better with the controls in the wet area and the heater itself outside the shower area, maybe this has been done. The reason these are popular in .uk is historical, mains pressure hot water was illegal for a long time, had to be tank fed (gravity). The increasing reliability of check valves allowed a loosening of these rules, but ...inertia

Echo The Husky

I would expect most to fail due to parallel earth paths bypassing the tripping coil, rather than never being tested. The mechanical parts in these are amazingly robust. They work great as main switches with the earth terminals ignored! The mechanical action is so smooth and satisfying to operate. (:

Chipmunk

if the circuit is designed right the leakage current is minor, to minuscule, open circuit element tho, ooof

Chipmunk

Mehdi would check it out by shocking himself convincingly on camera while not shocking himself (documented, he does this and admits it, he knows when to let go and make it look convincing, the MOT jacobs ladder was a famous OOOOOOOF that he's admitted still terrifies him)

Dave Frederick AKA @amorphuc

Guessing the one on the left. Kind of toasty looking. Could be that some resistors might have prevented that.

Big Clive

They all have 100K resistors. If that one had a 220K resistor it may have lasted a lot longer.

Electronics.Rocks

Still here 45 years (I am 57) later of daily use! So over 16000 uses! Ok had 6 units & current unit has had 3 repairs with a new unit ready under the bath! NEVER HAD A SHOCK OFF A UNIT! Lost count of how many UK electric showers I have fitted!

Electronics.Rocks

10 years is average life of UK shower. Usually the chamber starts to leak along the seal or dirt blocking the regulator, usually rust!

Electronics.Rocks

Still here 45 years (I am 57) later of daily use! So over 16000 uses! Ok had 6 units & current unit has had 3 repairs with a new unit ready under the bath! NEVER HAD A SHOCK OFF A UNIT! Lost count of how many UK electric showers I have fitted!

Big Clive

There's an increasing number of people being killed while charging their phones in the bath while using non compliant chargers. Unfortunately there's also a strong element of Darwinism involved there too.