Another video for this weekend.  It's a look at an interesting battery backed American style emergency exit sign that was generously sent to me by a chap called Andy.

https://www.youtube.com/watch?v=KbjLZmAWEmI

The design is a lot simpler than a typical UK version, but actually probably more rugged as a result.

Files

Previews only

Inside an American emergency light (with schematic).

This American style LED emergency light was sent by Andy for exploration. It's very neat, I like it. That might be because it's so different from the normal UK versions and has a certain "American appeal" to it. The design is simple and functional, and the choice of red LEDs means that it should put in a good long service life. Changing the battery pack is easy and the circuitry is simple, so it should last a long time if the transformer runs cool. The transformer is tapped for 120V and 277V for use with standard supplies or the higher voltage lighting circuits. Make sure you always insulate unused taps on transformers as explained in the video. The case has no screws and just snaps together which is an interesting approach. If you enjoy these videos you can help support the channel with a dollar for coffee, cookies and random gadgets for disassembly at:- http://www.bigclive.com/coffee.htm This also keeps the channel independent of YouTube's advertising algorithms allowing it to be a bit more dangerous and naughty.

Comments

Jamie Magin

480 volt is the phase to phase voltage in a lot of common industrial 3 phase stuff, 277 is the phase to neutral. (And then we have 208/120 typically in a lot of office situations so you can feed the regular 120 V single phase loads.) The 240/120 split phase common in residential service, i.e. single phase balanced around a 0 volt neutral seems to be quite a bizarre thing to Europeans.

Jamie Magin

(Also, running universal voltage 100-250 volt computer gear off the 208 phase-to-phase voltage is super common in commercial situations these days, usually with a rack-mount PDU that plugs into a 3 phase twistlock outlet and then presenting just female IEC connectors to be used with IEC-IEC cords so you don't plug ordinary loads in.)

Anonymous

I installed this EXACT sign two days ago and noticed how simple it's circuitry is.

Anonymous

Oh and I didn't cap the red wire and it gave me a good zap. Good note haha

TM

I wonder, is the extra capacitor large enough to cause a visible dip/flicker when testing the unit - to provide feedback that you've switched from AC to battery? I know one's I've tested have a flicker right after pushing the test button...

Anonymous

That sign just begs for a new faceplate that reads "Evil" instead of "Exit" :)

Anonymous

Great video's Big Clive I'm glad I jioned, one time you said you like to do more with Arduino, I'm into Halloween an Xmas allot and I'm looking to make some Prop controllers 4 and 8 channel with sound. it needs to control lighting, PWM motors, some drill motors, like the PicoBoo from Frightprops.com . but i know with your help it would be a lot better than there's. and i got some DMX lighting to add in Tell me what ya think, Keep up the good work

Big Clive

It's worth looking at some of the sites and forums dedicated to Halloween and Xmas tech. They often share information about their setups.

Michael Thompson

Here I was thinking that I'd hear about all kinds of cheap unpleasantness in the US one, but I end up hearing the opposite.

Anonymous

The bane of my existence. Got a building full of these - most only two years old. The batteries are very low quality and start dying about 8 months in. Always the same - 1 dead cell in each pack.