Home Creators Posts Import Register Favorites Logout

Content

Yep, that's pretty much all there is to it!

https://www.youtube.com/watch?v=pmKL3pgPQhY

Both videos will go live tomorrow. Timing on that is a little up in the air as I have an appointment in the morning.

Toodles!

Files

Tamper-resistant outlets aren't all the same - a follow-up

Yep. A follow-up to this video on the main channel: https://www.youtube.com/watch?v=vNj75gJVxcE

Comments

Mike Bird

My daughter, when she was 3-4ish, went to every outlet and pried out the plastic tab. She them brought them to me and was so proud of herself! She's now 34, has a 6yr & 6mo old, and lived in Japan. Which actually have worse outlets than the US has! She made sure that the floor level outlets had switches on them, but her 6 yr old figured those out when he was 3.

Mark Hesse

The best way to make North American household receptacles safer and to end any confusion is obvious: They should all be changed to NACS/Tesla connectors!😎 "One standard to rule them all!"

Juho K

Schuko is superior. For example the problem of shutters not working with the plug straight is not a problem with Schuko as it has the guide rails which force the plug in correct orientation. The guide rails also support heavy wall warts nicely and keep the plugs in very securely. The best feature is of course symmetry and the plugs fit both ways. Some people are freaked out by this and say it's less safe. I think it's actually safer as it forces to design appliances to be safe regardless of polarity. There's no guarantee that the socket is wired correctly which could be dangerous if safety depended on polarity. There is severe underappreciation on the internet for Schuko even though it is actually even better than the UK socket. Probably because Schuko isn't used in native English speaking countries.

Technology Connections

The one thing that Schuko is missing, though, is polarization. Of course, it's easy to design appliances such that this doesn't matter (DPST switches which isolate both sides) but not defining one side as hot vs. the other gives me the heebie-jeebies. And while it's easy to wire an outlet backwards, it's even easier to detect with an outlet tester.

Tim Janssen

Is there expert agreement that AFCIs sufficiently reduce risk to the point where outlet shock is very unlikely to cause harm? We have AFCI breakers on all child-accessible outlets and I assumed I was safe because of that. But curious to hear more.

Technology Connections

Unless it's a combo GFCI/AFCI breaker, it's probably not going to detect a shock. AFCIs aren't looking for leakage, they're looking for electrical noise indicative of arcing happening somewhere on the circuit which can lead to a fire.

Rob MacKenzie

Great vid! As for backstab, I've stopped using it, but still like Wago. The difference is that Wago 221 clamp down much harder. Try to twist and pull each out, I find you can get the wires out of backstab but not Wagos. I don't get the full hate either, but I'm never in such a rush that backstabbing would save that much time.

Cassandra Gelvin

Were you able to find any brands/styles of tamper-resistant outlets that were the safer type in the way you remembered them? If so, I'd like to know which ones they are, or how to find out (like if there's a term for that I can google). I have a box full of tamper-resistant outlets sitting under my desk because I read they are easier to use if they are "broken in" so I haven't installed them in my house yet.

Michiel Beijen

Hi there, European here. I also have the experience that in the US plugs fall out of their sockets. But I think this experience is caused by the travel adapters that we use. If you have your 65w MacBook charger with IEC7 plug hanging on a travel adaptor in a US socket where the travel adapter uses just the two pins, it will all fall out very easily, given the extra leverage due to the additional length of the contraption

MrHammond

When I was a kid (say about 2-3 years old) I tried to put screws into the outlet, well, I can say it hurt plenty, that's all I remember :-P... (yes, it was 220V, the GFCI tripped, which might have saved my life...). My father told me that when he was young, there was still 110V in parts of the Netherlands, he said "you just feel it a bit, not shocking at all". Later I got many shocks from working on tube devices (an old tube TV, and of course my Hammond organs), sometimes touching the 350V DC rail, but the voltage drops pretty quickly as soon as you touch it, you just feel it a bit. The worst shock was when I was working on the museum tram, somebody had put some coins in a 600V switch (DC, directly from the catenary, which can deliver several kA!) which had metal handles, that hurt pretty well! They told me to visit a doctor before going home, it is possible that you get heart damage from that which only kills you later! (go to bed OK, wake up dead!) Those tamper-resistant things we also have here, we had power strips in our band, they were worn out pretty badly, almost impossible to get any plug in there... At least: fail-safe 😜

Roland

With these tamper-resistant outlets you're creating a situation where it's harder to shoot your foot but you blow the whole leg off if you manage to anyways. From: a 50:50 chance hitting the live wire together with some other circumstances, which causes current to flow along the side of your body to ground and tripping the GFCI in the process. To: touching live and neutral simultaneously because you stuck two screwdrivers into the outlet, with your left and right hand. Now current is going across your heart and the GFCI won't trip because there is no fault current.

Buzzin

Same here, my dad told me that they used to have a similar system to the US 110v system in Amsterdam in his younger years. So 220v was two live wires combined :) I am glad we changed to 3 phase 240v though. And with GFCI on all fuses instead of just in the bathroom.

Peter

A GFCI won't trip for a fault on the low voltage side of a 24V transformer because the low voltage side is isolated from the high voltage side.

MrHammond

I lived for a couple of years in an old house in the centre of Gouda, we still had the double fuses for 2x 110V... I guess in that case, both pins on the outlet have live 110V instead of live and neutral.

Ryan Butler

My grandfather used to do his own electrical work without turning off the power. Saw his shoot across the room three times. Still died from diabetes not his obsessive need to never pay tradesmen.

Brian Condron

Was just going to make the exact same point, good thing I thought to look and see if anyone else had posted similar. My own experience is very similar, charger in a travel adapter in a hotel in San Francisco just fell out of the socket.

Theo Griffin

about the plugs falling out -- I regularly visit north america and have come across that issue every time. The charging bricks for phones, laptops, etc that plug directly in have a tendency to fall out, especially the somewhat larger/heavier ones. Gravity just pulls them out over time.

Jeremy

I appreciate how accessible you try to make this. That said, "ceteris paribus" seems like a succinct way to make comparisons. The couching to make that "term" (it is two Latin words, so it's plurality is suspect) accessible might be more trouble than it's worth. Great content, as usual. Really. This channel is flippin' awesome.

Kristian Høy Horsberg

The thing is that you can't actually guarantee that there is neutral on any of the pins for all of Europe. Most circuits in Norway have two hots and no neutral (although both hots are isolated from earth barring an earth fault).

Kristian Høy Horsberg

I've also experienced this. The trick is to bring your own power strip, plug the powerstrip into the outlet with the travel adapter, and plug your stuff into the power strip.

Michael Guerin

One of my nephews could do that when he was two years old. Just one of his many parent-scaring stunts. He has finally grown up but still does the odd silly thing simply to keep up his reputation.

For the Birbs (Jim Hooke)

The ironic thing is that the Australian and New Zealand plug and socket comes from the 1930's and was a discarded US design. A shame it didn't stick. The Aussie/NZ screw spacing for wall plates also matches the USA. The active and neutral pins/blades have half their length insulated as protection if plug partly comes loose. Protection against Alec's knife throwing... Oh, and a power switch as extra protection. https://www.plugsocketmuseum.nl/Australian-plugSocket_history.html